{"product_id":"victron-skylla-i-charger-24-vdc-100amp-2-bank-230-vac","title":"Victron Skylla-i Charger - 24 VDC - 100AMP - 2-Bank - 230 VAC","description":"\u003cp\u003e\u003cstrong\u003eSkylla-i Charger - 24 VDC - 100AMP - 2-Bank - 230 VAC\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eSkylla-i (1+1): two outputs to charge 2 battery banks. The Skylla-i (1+1) features 2 isolated outputs. The second output, limited to approximately 4 A and with a slightly lower output voltage, is intended to top up a starter battery. \u003c\/li\u003e\n\u003cli\u003eRugged Aluminium epoxy powder-coated cases with drip shield and stainless steel fixings withstand the rigors of an adverse environment: heat, humidity, and salt air. Circuit boards are protected with an acrylic coating for maximum corrosion resistance. Temperature sensors ensure that power components will always operate within specified limits, if needed by automatic reduction of output current under extreme environmental conditions.\u003c\/li\u003e\n\u003cli\u003eFlexible Next to a CAN bus (NMEA2000) interface, a rotary switch, DIP switches, and potentiometers are available to adapt the charge algorithm to a particular battery and its conditions of use. Please refer to the manual for a complete overview of the possibilities. \u003c\/li\u003e\n\u003cli\u003eSynchronized parallel operation. Several chargers can be synchronised with the CAN bus interface. This is achieved by simply interconnecting the chargers with RJ45 UTP cables. Please see the manual for details.\u003c\/li\u003e\n\u003cli\u003eThe right amount of charge for a lead-acid battery: variable absorption time. When only shallow discharges occur, the absorption time is kept short to prevent overcharging of the battery. After a deep discharge, the absorption time is automatically increased to make sure that the battery is completely recharged. \u003c\/li\u003e\n\u003cli\u003ePreventing damage due to excessive gassing: the BatterySafe mode. If, to quickly charge a battery, a high charge current in combination with a high absorption voltage has been chosen, the Skylla-i will prevent damage due to excessive gassing by automatically limiting the rate of voltage increase once the gassing voltage has been reached.\u003c\/li\u003e\n\u003cli\u003eTo increase battery life: temperature compensation. Every Skylla-i comes with a battery temperature sensor. When connected, the charge voltage will automatically decrease with increasing battery temperature. This feature is especially recommended for sealed lead-acid batteries and\/or when important fluctuations of battery temperature are expected. \u003c\/li\u003e\n\u003cli\u003eBattery voltage sense. In order to compensate for voltage loss due to cable resistance, the Skylla-i is provided with a voltage sense facility so that the battery always receives the correct charge voltage. \u003c\/li\u003e\n\u003cli\u003eSuitable for AC and DC supply (AC-DC and DC-DC operation). The chargers also accept a DC supply. \u003c\/li\u003e\n\u003cli\u003eUse as a power supply. As a result of the perfectly stabilized output voltage, the Skylla-i can be used as a power supply if batteries or large buffer capacitors are not available. \u003c\/li\u003e\n\u003cli\u003eLi-Ion (LiFePO4) ready Simple charger on-off control can be implemented by connecting a relay or open collector optocoupler output from a Li-Ion BMS to the remote control port of the charger. Alternatively, complete control of voltage and current can be achieved by connecting to the galvanically isolated CAN bus port.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cimg src=\"https:\/\/productimageserver.com\/prop65\/6pt.png\" alt=\"Warning\"\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals which are known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to \u003ca href=\"http:\/\/P65Warnings.ca.gov\"\u003eP65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\u003cstrong\u003ePlease contact your dealer for any returns, repairs or support issues related to this product.\u003c\/strong\u003e \u003c!--- cis2:m2lsnp1p ---\u003e\n\u003ch2 style=\"color:#1e3c0a; margin-bottom:20px;\"\u003e\n  Access More PDF Resources Below\n\u003c\/h2\u003e\n\u003ca href=\"https:\/\/productimageserver.com\/literature\/quickGuide\/82839QG.pdf\" style=\"display: inline-block; margin-right: 10px; padding: 10px 20px; background-color: #4CAF50; color: white; text-align: center; text-decoration: none; border-radius: 5px; font-weight: bold; cursor: pointer;\" target=\"_blank\"\u003e\n  Quick Guide Literature\n\u003c\/a\u003e\n","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":42290815500363,"sku":"SKI024100000","price":1393.15,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0588\/4621\/6267\/files\/82839XL.jpg?v=1775567009","url":"https:\/\/www.roamridge.com\/products\/victron-skylla-i-charger-24-vdc-100amp-2-bank-230-vac","provider":"Roam Ridge","version":"1.0","type":"link"}